ORION CE RF Quick Read-Single
The ORION CE RF Quick Read - Single screen is used to
perform a quick read on a single ORION ME endpoint serial
number using radio frequency (RF).
Figure 141: ORION CE RF Quick Read - Single screen
ORION CE RF Quick Read - Single Display Fields
S/N Enter the serial number of the ORION CE endpoint.
RSSI Received Strength Signal Indicator. The bar size increases as the handheld gets closer to the endpoint.
∆T Displays the number of seconds that have lapsed between transmissions. This field continues to
update during the quick read.
Status Any status alert displays in this field. Refer to "Status Codes" onpage112 for a list of codes.
Duration Displays the number of seconds since the Start button was tapped.
Tot. Count Displays the number of transmissions from the endpoint.
S/N Count Displays the number of endpoint readings currently showing on the screen.
ORION CE RF Quick Read - Single Buttons
Start/Stop Toggles to start and stop the quick read. Tap Start to start the quick read. Tap Stop to end the
quick read.
Reset Clears the current data, then continues to quick read.
To perform an RF quick read on a single endpoint, follow
these steps.
1. Tap in the S/N eld and use the handheld keypad or
the barcode scanner to enter the serial number of
the endpoint.
NOT: N Refer to "Barcode Scanner" onpage97
for steps on setting up the scanner for use.
2. Tap Start.
Result: Readings from the endpoint ll in the elds of
the table.
3. Tap Stop to end the quick read.