PROGRAM & QUICK READ
Program & Quick Read is used to perform a number of functions on ORION endpoints and touch modules. The most common
uses of Program & Quick Read include:
• Reading an endpoint or touch module (outside of the route reading process) when troubleshooting or testing at a
customer site.
• Reading one or more endpoints or touch modules prior to installation, to verify that the endpoints or modules are
working correctly.
• Clearing a tamper and reprogramming the odometer (RTR only) after the wire has been repaired.
• Testing a newly installed endpoint.
• Performing meter testing at the meter shop.
• Gathering a final reading from a meter.
NOT: N The handheld does not store Quick Reads and
cannot send any Quick Reads back to the reading
data management software.
Accessing Program & Quick Read
1. Access the ORION Field Application and navigate to
the Main Menu. If you need help, refer to "Program
Startup" onpage9 and follow the steps to access
the Main Menu.
NOT:N You do not need to have a route loaded to
access the Program & Quick Read software.
2. Tap Program & Quick Read.
Result: The Program & Quick Read Main Menu opens as
shown in Figure 76.
Figure 75: Main Menu
Two options are available on the Program & Quick Read Main Menu.
VersaProbe Opens the VersaProbe quick read software
application. Refer to page 45 for
instructions.
NOT:N For additional information about
VersaProbe, refer to "VersaProbe
Reads" onpage20.
ORION
Endpoint
Utility
Opens the ORION Endpoint Utility for
programming and quick read for ORION ME
and CE endpoints. Refer to page 46 for
instructions.
Figure 76: Program & Quick Read Main Menu
ORION® Automated Meter Reading System for Trimble® Ranger 3
Page 44 February 2013