Force Read (ADE, HR-E LCD)
When an ORION ME or SE (in mobile mode) endpoint is connected to an ADE or HR-E LCD encoder, the Force Read button
displays instead of the Program button. Force Read is used to view the real-time encoder odometer value and to verify a
successful tamper repair.
1. Align the optical read head of the IR cable with the
ORION ME endpoint IR port.
2. Tap Force Read.
Result: The reading value updates to reect the current
encoder odometer value. Reading will display if the
tamper condition no longer exists.
Figure 89: Force Read on ADE
Listen
The Listen button activates the radio frequency to listen for a reading from the endpoint when in mobile mode. Tap the
Listen button to display the RF quick read information for the selected endpoint.
For additional information, refer to "ORION ME RF Quick Read-Single" onpage64.