High Resolution (HR) E LCD Extended Status
Figure 92: Extended Status - HR-E LCD
The status indicators described below apply for an ORION ME or SE (mobile mode) endpoint when connected to an
HR-E LCD encoder.
Status Indicator Description
EP Prog Endpoint is reporting that it has been reprogrammed via IR.
EP Tamper Endpoint is reporting a tamper condition. This condition occurs when the wire between the
encoder and the endpoint is cut or shorted, or the encoder is not connected.
Mobile Mode Endpoint is communicating in mobile transmission mode.
EP Low Battery Endpoint is reporting a low battery condition.
Encoder Error Encoder is reporting a device error to the endpoint.
Removal Encoder is reporting an encoder removal condition to the endpoint.
Temp Encoder is reporting to the endpoint that it senses temperatures outside the specified range.
ENC End of Life Encoder is reporting to the endpoint that the encoder battery life indicator has been activated.
No Usage Encoder is reporting a no usage condition to the endpoint.
Reverse Flow Encoder is reporting a reverse flow condition to the endpoint.
Leak Encoder is reporting a potential leak condition to the endpoint.
ENC Prog Encoder is reporting to the endpoint that the encoder has been reprogrammed via IR.
Mag Tamper Encoder is reporting a magnetic tamper condition to the endpoint.
Encoder Information Description
Size & Type The size and type of the meter for which the encoder was programmed.
Units The units of measure as defined by the encoder: cubic meters, cubic feet, gallons, imperial gallons
or liters.
Encoder The encoder protocol.
Dials Encoder dial resolution (8) as reported from the encoder.
Reverse Flow Total The total reverse flow units measured by the encoder.
NOT: N Refer to the HR-E LCD Encoder Installation and Programming manual, LCD-IOM-1-EN, for a detailed list of encoder
status indicators.