1. Double-tap the reading in the box to the right of
the Reading eld.
Result: The current reading in the eld is highlighted.
Figure 86: RTR Reading field
2. Using the handheld keypad, enter the RTR odometer value in the Reading eld.
Result: The inside of the reading box turns pink (Figure 87) to indicate a new value is entered in the eld but not yet
programmed.
Leading zeros are not required, however it may be helpful to enter leading zeros as visual confirmation. Only seven
digits can be entered when programming an endpoint, regardless of the meter size.
3. Align the optical read head of the IR cable with the ORION ME endpoint IR port and tap Program.
Result: The new value is programmed and the reading box is no longer pink. See Figure 88.
Figure 87: New reading is entered
Figure 88: New reading is programmed
NOT: N When programming an endpoint after clearing a tamper, verify that the programming and wire splicing were
successful. Tap ORION ME RF Quick Read - Single and tap Start Reading to perform a Quick Read on the endpoint.
If the endpoint still reports a tamper, check the wire splices, repair as necessary and repeat the programming
procedure above.
It is unnecessary to Stop an endpoint before fixing a tamper. If an endpoint has been stopped,
tapping Start clears the historical interval data (profile data) and places fixed mode endpoints
into mobile mode. Endpoints in mobile mode may not revert to fixed mode for up to 48 hours.