Security Ranger III Betriebsanweisung Seite 68

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 124
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 67
ME Profiling Fields and Buttons
Oldest Reading The date and time of the oldest reading in the data extracted.
Interval The reading interval at which the endpoint is set: 60 (every hour) or 15 (every quarter hour)
Quantity Displays the number of interval reads retrieved.
Consumption The difference between the start and end reads in the profile requested.
Status(es) Displays any potential issues that require attention. Example: tamper, no usage, etc.
Change Interval Tap to change the reading interval for the endpoint. A message asking for confirmation displays
before and after changing the interval. All currently stored profile data is erased when the interval
is changed.
Clear Endpoint Tap to erase the stored historical interval data for the endpoint.
Save Saves the extracted data on the handheld. The .csv file may be viewed with the ORION Profile
Viewer software.
When you select Save, the software prompts you to select the meter type before you save the file.
A confirmation message displays to show where the file is saved on the handheld. The file location
path includes the endpoint serial number and the date and time.
Example: \Program Files\Badger Field Applications\Mobile Read.Net\ProfileExtraction\
LogFiles\30000264 20120605 115349.csv
This chart shows the number of readings collected for meters set at 60 minute (hourly) intervals and at 15 minute (quarter
hourly) intervals:
Available Prole Data
Extraction Intervals
Hourly Reads:
1 Read per Hour
24 Reads per Day
15 Minute Reads:
4 Reads per Hour
96 Reads per Day
7 days 168 reads (24 x 7) 672 (96 x 7)
14 days 336 reads (24 x 14) 1344 (96 x 14)
30 days 720 reads (24 x 30) 2160 (96 x 22.5)
60 days 1440 reads (24 x 60) 2160 (96 x 22.5)
All/ 90 days 2160 reads (24 x 90) 2160 reads (96 x 22.5)
NOT: N The ORION ME endpoint (or SE in mobile mode) is capable of storing up to 90 days of hourly interval data, or 2160
hourly reads. If the account is set up to read every 15 minutes – 4 readings per hour – the data extracted reflects four
(4) readings per hour and reaches the maximum 2160 reads in 22.5 days (90 days / 4 = 22.5 days).
ORION® Automated Meter Reading System for Trimble® Ranger 3