High Resolution (HR) E-Series Extended Status
Figure 93: Extended Status - HR E-Series
The status indicators described below apply for an ORION ME or SE (mobile mode) endpoint when connected to an
HR E-Series meter.
Status Indicator Description
EP Prog Endpoint is reporting that it has been reprogrammed via IR.
EP Tamper Endpoint is reporting a tamper condition. This condition occurs when the wire between the
E-Series meter and the endpoint is cut or shorted, or the encoder is not connected.
Mobile Mode Endpoint is communicating in mobile transmission mode.
EP Low Battery Endpoint is reporting a low battery condition.
Encoder Error E-Series meter is reporting a device error to the endpoint.
Empty Pipe E-Series meter is reporting a no flow condition in the pipe.
Low Temp E-Series meter indicates the low temperature limits have been exceeded.
ENC End of Life E-Series meter is reporting to the endpoint that the encoder battery life indicator has been
activated.
No Usage E-Series meter is reporting a no usage condition to the endpoint.
Reverse Flow E-Series meter is reporting a reverse flow condition to the endpoint.
Leak E-Series meter is reporting a potential leak condition to the endpoint.
Sensor Error Endpoint is reporting a sensor error or meter alarm other than empty pipe or low temp.
Encoder Information Description
Size & Type The size and type for which the E-Series meter was programmed.
Units The units of measure as defined by the E-Series meter: cubic meters, cubic feet, gallons,
imperial gallons or liters.
Encoder The encoder protocol.
Dials Encoder dial resolution (8) as reported from the E-Series meter.
Reverse Flow Total The total reverse flow units measured by the E-Series meter.
NOT: N Refer to the E-Series Installation and Programming manuals, ESM-IOM-01-EN and ESM-IOM-02-EN, for a detailed list
of encoder status indicators.
Installation & Operation Manual
Page 57 February 2013